Kit Includes PVC Ptrap Kit, 50' Line Set 1/2" Insul, PVC Adapters/Fittings, Whip 6' 1/2" 10GA, Furnace Leveler, No Vent Caps, 2" Plastic Pad, 2H/2C Thermostat, Disconnect
Motor Freight
Vendor Name:
Arcoaire
URI Part Number:
Arcoaire AC Single Phase Split System Deluxe Single Stg 1.5 Ton 24k BTU AHU 15.5 SEER2
Shipping Weight (Lbs.):
200
Energy Star:
Energy Star 6.1 Compliant: 15.2 SEER2, 12.0 EER2
Includes:
H4A6S18AKAWA, FMA4X2400AL, ACBKIT2
Nominal Capacity (BTUH):
18000
Cooling Efficiency (EER2):
13
Cooling Efficiency (SEER2):
15.5
Heating Efficiency HSPF2:
A/C is Energy Star 6.1 compliant
System Indoor Type:
AHU
System Outdoor Type:
Single Stage
System Coil Configuration:
Front Return
System AHU Type:
Specialty AHU (Uncased, Apartment)
System Nominal Tons:
1.5
AHRI System Number:
207908881
A/C, Single Phase, Split AHU Single Stage, Front Return H4A6S/FMA4
Air Conditioner Condenser
80% AFUE
Flame roll-out sensors standard
Category I venting
Blocked vent switch
Louvered door
24 VAC and 115 VAC humidifier terminal
Electronic air cleaner terminal
Select sizes approved for twinning, refer to accessory kit listing
N80ESL - Low NOx units are designed for California installations and can be installed in air quality management districts with a 40ng/J NOx emissions limit
Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193
Adjustable heating blower OFF delay
Factory set blower ON delay
RPJ aluminized steel heat exchanger
High temperature limit control designed to prevent overheating
Direct ignition with Silicon Nitride igniter
One piece prepainted steel cabinet
In-shot burners
33 1/3” (847mm) high, for ease of installation
Quarter turn knobs for easy door removal and secure attachment
Factory shipped for natural gas, convertible to propane with accessory kit
Four position - upflow/downflow/horizontal (left/right) installation
Three position inducer elbow capability
Through the casing flue pipe for counterflow applications
Common venting with other Category I appliances
Masonry chimney adapter available
Self diagnostics
Slide out blower assembly
Front Return Fan Coils
Factory installed TXV (4X) - Piston (4P)
EC motor (4X) - PSC Motor (4P)
Motor suspended on rubber grommets for quieter operation
Standard return air grille panel and is convertible to bottom return
Replaceable air filter factory supplied with all models
Fully insulated for conditioned space (not to be installed in unconditioned spaces)
Upflow application only
208/230-1-60 supply voltage
Fresh air intake holes (capped from factory)
Units fits between standard stud spacing
All service access is located in the front
Primary and secondary drain connections exit from the bottom
No return-air ductwork required in specific applications